Solenoid operated Relay

The solenoid operated relay has a coil wound around a core that produces magnetic field when the coil is energised by the current flowing through it. The magnetic field pulls the lever (movable contact) to either make or break the contact.

Solenoid Relay with Pushbutton

This relay has a push button instead of a lever. The energized coil pulls in the pushbutton either making or breaking the contact.

Generic Relay

A relay is an electrical switch that has a set of control terminal & contact terminals. The control terminals is operated by a single or multiple control signals to swtich the contact terminals. They are used for switching relatively high power circuits using low power signals.

Double Coil Relay

These type of relays has two coils. Each coil has separate control terminals. Either of the two coils are used for making or breaking contact. When coil 1 is energized, it makes contact while energizing coil 2 breaks the contact. Double coil relay are mostly latching devices whose contacts remains in their position even after de-energizing the coil.

Double coil relay with opposite direction of windings

Such type of double coil relay has windings in opposite direction to each other. The magnetic field produced by one coil is opposite to another. Each coil changes the contact position when energized.

Overcurrent Relay

Overcurrent relay is a protective relay that activates when the current exceeds a limit to protect the system. It basically isolates the system from the fault current by breaking the contact in between.

Under Current Relay

It is also a current protection relay used to protect system or circuit from low current. It is activated when the current decreases from a specified limit.

Differential Current Relay

Differential relay operates on the phase difference between the input & output current of a system. If there is any difference that means there is presence of fault current thus it starts switching. They are used for protection of transformers, feeder & motors etc.

Fast Deactivation Relay

As the name suggests, such type of relays has a very fast deactivation speed. As soon as the power supply is removed from the coil, the coil de-energizes immediately & thus switches the contact.

Slow Excitation Relay

Such type of Relays has a slow operating coil. There is a time delay during the excitation of the coil to switch the contact terminals.

Slow Deactivation Relay

Such type of relay has a time delay when the power supply is removed from its control terminals. There is capacitor connected in parallel that keeps the coil energized for a specific time depending on its characteristics. After the capacitor discharge, the coil de-energizes & switches the contacts.

Fast Switching Relay

This is a fast switching relay that can instantly switch from activated state to deactivated state very fast & vice versa. The coil of such relay energizes or de-energizes as soon as the power supply is applied or removed respectively. They are used for instant switching applications.

Defective Voltage Relay

Such type of protection relay is activated by defective voltage in line. When there is a voltage fault in the line that could cause damage to the equipment, the relay activates to prevent such damage.

Card Access Relay

This is an electronic relay that operates on special cards. Most card access relays are wireless relays that identify the card & wirelessly passes the signal to the relay to activate or deactivate. These are used for security purposes.

Relay Unaffected by AC

Such type of Relay coil does not get affected by alternating current.

Differential Relay

Differential relays operate on the difference between two electrical quantities. They activates when the specified difference exceeds or decrease a fixed limit. Most differential relays are protective relays used to protect the systems.

Polarized Relay

Polarized relay is a type of relay whose switching depends on the direction of the current flow through the coil. Some relays are magnetically polarized other by using a diode in series with the coil that prevents the current flow in reverse direction.

Magnetically Polarized Relay

Polarized relay are made up of electromagnetic coil and a permanent magnet. The magnetic flux of the coil distorts the magnetic flux of the permanent magnet to switch the contacts in either position. There are mostly three positions in these relays. Normally it is in neutral position & the direction of the current flow switches it into either of the other two positions.

Electromagnetic Relay

Such type of relay has an electromagnetic coil which is energized by supplying AC or DC current. The coil produces magnetic field which attracts the lever (contact) to make or break contact.

Thermal Relay

Such type of relay operates on the temperature. There is a bimetallic strip that bends when exposed to heat. The heat produce element inside the relay due to heavy current bends the metal strip to break or make the contact. These are used in overload protection for machines.

Solid-State Relay

Solid-State Relay (SSD) is a type of relay that is made of semiconductors & uses optocoupler to switch the main circuit. It has no moving or mechanical parts so they have more lifespan as the mechanical contacts wear out with switching. There is no switching noise or effect of vibration or movement on its switching.

Stepping Relay

Stepping relay is a type of relay that directs the input current through one of many output terminals using a series of control pulses. The pulses move the contact arm by rotating in steps to connect it one of the multiple output terminals.

Remote Control Relay

Such type of relays is operated by a wireless remote control. These relays enable the user or any system to operate it without any physical or electrical connection. They relay can switch on/off or switch to one of multiple outputs depending on its type.

Pulse Relay

Pulse relay is a type of latching relay that is activated by a voltage pulse. It retains its position i.e. either OFF or ON until there is a voltage pulse.

Remanance Relay

The remanant or remanance relay is a type of latching relay that retains its position due to the remanance magnetic field in the core. The core is de-energized by current flow in reverse direction.

Intermittent Relay

Such type of relay has a time delay function. Once activated, Its contacts closes after a fixed amount of time & then reopen it. It repeats the cycle until the power supply is removed.

Solenoid Valve

The solenoid valve is an electromechanical valve that is used to regulate the flow of any liquid or switch the flow of liquid into other ports. There are different type of solenoid valves depending on current and its mechanism.

AC Relay

As the name suggest, the coil of such relay is only energized by supplying an AC current. The alternating current produces a varying magnetic field in the coil which results in attracting the contact terminal.

ON/OFF Time Delay Relay

It is the symbol for representing a relay that has a time delay function for both activation & deactivation. The contacts of such relays turns on & off with adjustable time delay to provide pulses of power. Flashing light are prime example of time delay relay applications.

Mechanical Resonance Relay

Such type of relay detects the mechanical resonance in a system & activates when the resonance occurs. Mechanical resonance is the phenomenon when the mechanical frequency becomes equal to the natural frequency of the system. In this case the resonance frequency is 25Hz.

Interlock Relay

Interlock relay is made up of two or more than two coils with individual contacts & the energizing of one coil depends on the contact’s position of the other coils.

Reed Relay

The reed relay is made of magnetic contact encapsulated in a tube filled with inert gas. The contacts are enclosed inside an electromagnetic coil. The contact connects when the coil is energized or if there is an external magnetic field. It is very fast & sensitive to low currents but it has very low current & voltage ratings.

Overvoltage Relay

Such type of protective relay is used for protection against high voltage. . It is activated when the voltage exceeds from the specified relay voltage limit.

Under voltage Relay

This is also a protection relay but it activates when the voltage level decreases from a pre specified limit. It protects the circuit from low voltage.

No Volt Relay

Such type of voltage protection relay detects the presence of the voltage. When the voltage supply is removed, it activates. It is used in motor starters to increase the resistance when the voltage is removed so that the motor does not automatically start with low armature resistance (that can damage it).

Distance Relay

The distance relay or impedance relay operates on the impedance between the fault in line & its installation point. The impedance is measured by the current & voltage ratings from CT & PT. Once the impedance decreases from the relay impedance limit, the relay activates.

Broken Conductor Protection relay

Such type of protection relays are used for detection of broken conductor in a 3 phase power system. It operates on the ratio of Positive sequence current (I1) to negative sequence current. The ratio increases significantly with a broken phase & the relay activates the alarm system.

Under Power Relay

Such type of protective relay keeps the power wattage supply in check. As soon as the power decreases from its threshold it activates to break or make contact.

Short Circuit Protection Relay in Coils

This relay detects the short circuit between the turns of coils & activates the protective measure to prevent the systems from more damage.

Reverse Current Relay

Such type of relays breaks the contacts when there is a current flow in reverse direction. It is used in DC generators when the voltage of the battery is higher than the generator, the relay disconnects to stop the discharging of battery.

3 Phase Failure Detection Relay

It is a protection relay used for 3 phase load such as motor or other equipment to prevent it from starting because of damage or burnout during an open phase or failure in any phase.

Overcurrent / Undercurrent Relay

Such protection relay is used for protection against low or high current. As long as the current stays in its limit the relay does not activate but as soon as the current crosses any (faulty current) limit the contacts break to protect the circuit.

Motor Stalling Relay

Stalling in motor is a condition when the winding are energized but the rotor does not rotate. During stalling, motor draws huge current that can cause overheating. It is because of heavy load at start or loss of a phase. Stalling relay protects the motor from such condition.

Frequency Relay

This type of relay operates on the frequency of the power system. They are used for detection & protection against abnormal frequencies (under frequency & over frequency) in generators etc. If the frequency exceeds or decreases from the specified limit, it activates to switch the contacts.

Automatic Reclosing Relay

Such type of relay can automatically reclose after being open due to a power failure. They are used in power systems where the fault can clear themselves after a failure. If the fault still exists, the relay locks the contacts in open after a few tries.

Overcurrent Relay with Time delay

Such type of protection relay against current adds in a time delay function. They are used in power system that can handle high current for a short duration of time. If the current remains high for a specified duration, the relay breaks the contact.

Monitoring Relay

Such type of protection or alarm relay monitor or measure the electrical quantities & protects the circuits against them when they exceeds its limit. The asterisk is replaced with the symbol of that quantity. The types of monitoring relays are over voltage/current, under voltage/current relays etc.

Electromagnet

Electromagnet is a wire wounded in a coil around a magnetic core. The current flow through the coil creates a magnetic field which is amplified by the magnetic core. It is used in relays to actuate the contact terminals.

Open Contacts

These are the symbols used for representing the open contacts of a relay. It means the contact is break & there is no flow of current

Closed Contacts

These symbols represent closed contacts or make contact. The contacts are short & the current can flow through it.

Normally Open Contact

This symbol represents the contacts of a relay that are open under no power supply. The circuit is break & there is no current flow. When the relay activates, the contacts are made & it start conduction.

Normally Closed Contact

It is the contact of relay that is in closed position when there is no power supplied. the contacts open when the relay activates to break the circuit.

Changeover Contact

This is the changeover contact of a relay that is closed or connected with one terminal (known as normally closed terminal) when the relay is deactivated & the other terminal is open (known as normally open terminal). It changes the contact’s position when the relay activates.

Switch

These two symbols represents the switch part of the relay that is used for switching on/off or switching the current from one terminal to another.

More Electrical & Electronics Engineering Symbols:

  • Basic Electrical and Electronic Symbols
  • Transformer Symbols
  • Motors Symbols
  • Generator and Alternator Symbols
  • Resistor Symbols
  • Capacitor Symbols
  • Inductor Symbols
  • Fuse and Circuit Breaker Symbols
  • Switch and Push Button Symbols
  • Diode Symbols
  • Transistor, MOSFET and IGFET Symbols
  • Thyristor, DIAC and TRIAC Symbols
  • Electronic Logic Circuits and Programming Symbols
  • Digital Logic Gates Symbols
  • Digital Flip-Flop and Latches Symbols
  • Electronic Filters Symbols

Tags

Coil Electrical Symbols Electromagnet Electronic Symbols Relay Solenoid SSR Relay

Relays Symbols. Coil, Solenoid, Electromagnet & Contacts Symbols (2024)

FAQs

What is the symbol for a relay coil? ›

Understanding the different components of a relay symbol

The coil is usually represented by a zigzag line and is responsible for generating the magnetic field required to actuate the relay. The contacts represent the actual switching mechanism and can be either normally open (NO) or normally closed (NC).

What are the coils and contacts of a relay? ›

A relay is an electrically operated switch. They commonly use an electromagnet (coil) to operate their internal mechanical switching mechanism (contacts). When a relay contact is open, this will switch power ON for a circuit when the coil is activated.

What is a relay quizlet? ›

What is a relay? Electrically operated switch, designed for normally open switches or normally closes switches.

What is a contactor symbol? ›

The contactor symbol consists of three parts: coil, main contacts and auxiliary contacts. There can only be one coil in a contactor. The main contacts of a contactor are three and are always drawn as one symbol in the form of three contacts.

What is the electrical symbol for solenoid? ›

The symbol for the solenoid or the pressure- operated valve has the same number of squares as the valve has positions. The right-hand square shows the valve in its non-actuated (rest) position, the left-hand square corresponds to a valve in its actuated (work) position.

What is a relay coil for? ›

Relay consists of a coil, which receives an electric signal and converts it to a mechanical action and contacts that open and close the electric circuit.

What should a relay coil read? ›

On a four or five-pin relay, these are pins 85 and 86. If you get a measurement between 50 and 120 ohms, the coil is likely good. Anything out-of-spec means that the coil winding is bad and you'll need a new relay.

What is the difference between a contactor coil and a relay? ›

The main difference between a contactor and a relay is their load capacity. Contactors are designed to handle high currents, typically above 15 amps, while relays are more suitable for low to medium current loads, usually below 15 amps.

What is the common contact on a relay? ›

The COM (Common) connection of a relay is the part of the relay that moves. When a relay is off, the COMMON is connected to the NC (Normally Closed). The NO (Normally Open) connection of the relay is not connected until the relay turns on. When the relay turns on, the COMMON move from NC to NO.

What is a relay short answer? ›

Relays are electrically operated switches that open and close the circuits by receiving electrical signals from outside sources. Some people may associate “relay” with a racing competition where members of the team take turns passing batons to complete the race.

What are relays explained simply? ›

Relays are switches that open and close circuits electromechanically or electronically. Relays control one electrical circuit by opening and closing contacts in another circuit.

What is relay basics? ›

Relay consists of a coil, which receives an electric signal and converts it to a mechanical action and contacts that open and close the electric circuit.

What are the basic electrical symbols? ›

There are five commonly used symbols in Electrical – Switch, Wire, Contactor, Motor, Transformer. These symbols can be used in any electrical drawings. Switches are used for ON/OFF any control circuit. Contactors are used to ON/OFF any electrical equipment through electrical signals.

How to read an electric diagram? ›

Follow the Flow: Electrical schematics are typically read from left to right, with the power source on the left and the ground on the right. Follow the flow of the lines to understand how current travels through the circuit. Identify Components: Identify each component in the schematic and understand its function.

What is the symbol of a resistor? ›

2.3 Resistor Symbols and Marking Symbols

In general, resistors are usually represented by symbols such as R, RN, RF, and FS. In the circuit, the symbol of the fixed resistor and trimming resistor is R, and the symbol of the potentiometer is RP.

What is the current coil of a relay? ›

Typical relay coil currents are well below 1 amp, while typical contact ratings for industrial relays are at least 10 amps. One relay coil/armature assembly may be used to actuate more than one set of contacts. Those contacts may be normally-open, normally-closed, or any combination of the two.

Is there a relay for ignition coil? ›

At its base, the ignition system refers to the elements that provide the spark through the ignition coil. In that case, the ignition relay would power up the coils (like the ASD relay on a Chrysler-based platform) and the trigger for the coils will come from a module or the PCM.

What is the coil side of a relay? ›

Relays involve two circuits: the energizing circuit and the contact circuit. The coil is on the energizing side, and the contacts are on the contact side. When the coil is energized, current flows through the coil creating a magnetic field.

What are the connector terminals for the relay coil? ›

Relay Guide
Terminal/Pin number and sizeConnection
1 (86) - 4.8mmCoil
2 (85) - 4.8mmCoil
3 (30) - 6.3mmCommon connection to NO & NC terminals
4 (87a) - 4.8mmNormally Closed (NC) - not present on 4 pin relays
1 more row

Top Articles
Latest Posts
Article information

Author: Clemencia Bogisich Ret

Last Updated:

Views: 6243

Rating: 5 / 5 (60 voted)

Reviews: 91% of readers found this page helpful

Author information

Name: Clemencia Bogisich Ret

Birthday: 2001-07-17

Address: Suite 794 53887 Geri Spring, West Cristentown, KY 54855

Phone: +5934435460663

Job: Central Hospitality Director

Hobby: Yoga, Electronics, Rafting, Lockpicking, Inline skating, Puzzles, scrapbook

Introduction: My name is Clemencia Bogisich Ret, I am a super, outstanding, graceful, friendly, vast, comfortable, agreeable person who loves writing and wants to share my knowledge and understanding with you.